Shenzhen INVT Electric Co.,ltd.
|
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Mini Inverter INVT Vectorization VF Control , Three Phase Inverter CE / TUV
Advantages
1. VF control;
2. Natural cooling(for the applications with cotton and dust);
3. Mini structure,less installation space.
Description
Goodrive 10 Series mini economy inverters are designed for the small power OEM application market.With the function of vectorization VF control and PID function,multi step speed, DC braking and modbus communication and so on,the inverter has more advantages but occupied less istallation space.
Fatures
1. Standard modbus communication;
2. Built-in PID;
3. 16 steps multi step speed control;
4. Flexible VF curve setting;
5. Multi function I/O terminal(the delay time can be set);
6. Fault protection at overcurrent,overvoltage,undervoltage,overtemperature and overload with detailed fault information;
7. DC braking,flux braking and resistor dynamic braking;
8. Overcurrent and overvoltage stall,stronger load adaptability.
Applications
Packaging machinery,food machinery,textitle machinery,centrifuge,engraving machine,and cutting machine,etc.
Specifications
Function |
Specification |
Input Voltage(V) |
Single phase 220(-15%)-240(+10%) Three phase 220(-15%)-240(+10%) Three phase 380(-15%)-440(+10%) |
Input Frequency(Hz) |
50Hz or 60Hz Allowed range:47-63Hz |
Output Voltage(V) |
Equal to input voltage with the deviation of less than 5% |
Output Frequency(Hz) |
50Hz/60Hz, Fluctuation range:±5% |
Control mode |
V/F |
Maximum output frequency |
400Hz |
Adjustable-speed retio |
1:100 |
Overload capability |
150% of rated current:1 minute,180% of rated current:10 seconds, 200% of rated current:1 second |
Terminal analog input resolution |
≤20mV |
Terminal switch input resolution |
≤2ms |
Analog input/output |
1 input 0-10V/0-20mA; 1 output 0-10V/0-20mA |
Digital input/output |
5 common input, 1 Y output(commonly used with digital output) and 1 rogrammable relay output |
Communication |
485 communication |
Mountable method |
Wall mountable |
Temperature of the running environment |
-10 – 50,derate above 40 |
Cooling |
Single/Three-phase 220V 0.2-0.75kW natural cooling |
Single/Three-phase 220V 1.5-2.2kW, Three-phase 380V 0.75-2.2kW |
|
Fault protections |
Overcurrent, overvoltage, undervoltage, overtemperature, overload and other protections |
Braking unit |
Only standard for GD10-B |